The process that takes place when blood is being oxygenated can be monitored through and equipment known as CMS pulse oximeters. The levels of oxygen in the body should always be above ninety five percent. These devices are non-invasive, their utilization is by the medical professionals to their patients to be able to maintain the required levels of oxygen in the body. You can be able to find these equipments in areas such as intensive care, operation theatres, treatment ward and recovery area in the hospital facility.

These devices measure accurately and are used to detect even the slightest of changes in blood oxygenation . Even though these medical facilities have a long history, they were spread widely in the 1890s. This is how they function; the oxygen monitor which has a tiny probe is clipped to a spot with good blood flow. This spot can be a finger or an earlobe.

After clipping the spot, the monitor is fixed to a separate computerized unit specialized to show the readings. The Inside of the probe has a light emitter which sends out two light streams. One of them is red and the other infrared. Then, the steams of light produced are received and measured using a photo detector that is right opposite the emitter.

Typically, the oxygenated hemoglobin takes in a larger amount of the infrared light . The red light is allowed to pass through. It is the vice versa when it comes to the deoxygenated blood. It actually absorbs more red lights and allows the infrared light to pass through. The level of oxygenation in the patient blood is calculated by the oxygen monitor. This is determined by measuring the amount of light which is absorbed by the blood hemoglobin at both wavelengths.

When the oxygen monitoring device detects any oxygenation change of a patient suffering from anesthesia, it is necessary to raise an alarm. This is because it might cause a heart failure or brain damage if the body lacks sufficient supply of oxygen for even three minutes. Therefore early diagnosis is very important for one health.

As mentioned early, a healthy body should never fall below 95 percent of O2 saturation. The good thing with these monitoring devices is that they are able to detect a change as small as one percent. Before oxygen monitors were discovered, healthcare practitioners would only manage to detect oxygen starvation when the patient is already at very critical conditions.

There are various types of oximeters. They include pediatric which can be a wrist, handheld or finger oxygen monitor. These monitors are specifically designed for children and they produce results that are so accurate. They are made of features that help in sensing the best finger for testing and its right position. Unlike when these devices were too large and quite expensive for patients to own them, nowadays they are portable, affordable and available in the market.

There are many versions of cms oxygen monitors available today but the most effective ones are the finger models. They are also very affordable. They are sold as from 30 dollars, including delivery. These devices are used for treating pneumonia as well as neonatal blindness by anesthesiologists .